According to IEC: 61000-4-5
-Model Number: KT - 6030iG
Specification:
Test output wave form (Combination wave)
(1) (a) Output voltage: 0 ~ 6 kV ( No Load)
(b) Wave form: T1 (Rising Time) = 1.2 ± 0.36 us
T2 (Pulse width) = 50 ± 10 us
(2) (a) Output current: 0~3000 A (Short Circuit)
(b) Current wave form: T1 (Rising Time) = 8±2.4us
T2 (Pulse width) = 20+8, -4us
(3) Observation for Oscilloscope
1- voltage = 1/1000 dividing by BNC connector
2- Current= 1/1000 dividing by BNC connector
(4) Operation
(a) Manual =Trigger Button
(b) Auto = Counter timer for Auto Trigger
(5) Remote Button
(a) Trigger
(b) Stop
(6) Dimension
660 W x 1280 H x 760 D (mm)
Weight = Approximately 110 kg.
(7) Delivery Time = 45 Days after T/T Remittance
(8) Package = Standard wooden package
Use= For the AC Power lines against lightning strike